FICTIONAL SAMPLE - Contoso Renewables, Quellmoor Ridge Wind Farm and every organisation, person, product and value in this wiki are invented. Not for operational use.

LWS-P-30422 is a spare part referenced in the LT-32 Maintenance Manual gearbox alarm guidance.1 It is listed as a valve insert to check when alarm A2101 reports high gearbox oil sump temperature.1

Facts

  • Alarm A2101, Gearbox oil sump temperature high at 75 °C, can be caused by cooling, oil level, load/ambient-temperature, or bearing issues; actions include checking fan rotation and motor current, cleaning the radiator, checking valve insert LWS-P-30422, checking oil level, reviewing vibration trend, and taking an oil sample.1

Timeline

No dated facts.

Documents

Sources

Footnotes

  1. LWS-MM-GBX-32 Rev. D — LT-32 Maintenance Manual Chapter 4 Gearbox Excerpt — p. 5 · ✓ quote verified ↩ ↩2 ↩3