Quellmoor Ridge O&M wiki

Fictional sample. Every organisation, person, site and document in this wiki is invented. Not for operational use.
Home

/

Evidence

/

Evidence for 8D report INC-2026-006 - Repeated gearbox oil over-temperature on WTG-07 (revision 2026-07-10)

/

8D report INC-2026-006 - Repeated gearbox oil over-temperature on WTG-07 (revision 2026-07-10) — ¶ 14

8D report INC-2026-006 - Repeated gearbox oil over-temperature on WTG-07 (revision 2026-07-10) — ¶ 14

Oct 18, 20261 min read

Source page: 8D report INC-2026-006 - Repeated gearbox oil over-temperature on WTG-07 (revision 2026-07-10) · Original file: original.docx · Provenance: ✓ quote verified (native text)

Text

Why 3 - Why did the fan run slowly? The bearing of the fan motor LWS-P-30418 had failed; the motor current was 35 % above nominal.


Graph View

Backlinks

  • LWS-P-30418
  • Evidence for 8D report INC-2026-006 - Repeated gearbox oil over-temperature on WTG-07 (revision 2026-07-10)
  • 8D report INC-2026-006 - Repeated gearbox oil over-temperature on WTG-07 (revision 2026-07-10)
  • Gearbox temperature, vibration and oil analysis

Built with DocWiki and Quartz v4.5.2 · release 20261018T104207Z-650d6d98 · audience public