FICTIONAL SAMPLE - Contoso Renewables, Quellmoor Ridge Wind Farm and every organisation, person, product and value in this wiki are invented. Not for operational use.
The Fabrikam FGT-3200 is a three-stage gearbox used on Litware LT-32 turbines, with one planetary stage followed by two parallel helical stages.12 Its rated input torque is 2,410 kNm and its dry mass is 21.6 t.2 Only the lubricant listed in Table 4-2 is approved for the FGT-3200 gearbox, and lubricants of different brands or viscosity grades must not be mixed.3
Facts
- The bulletin applies to LT-32 turbines delivered in CCV configuration with Fabrikam FGT-3200 gearboxes and to LT-32 standard turbines at sites where ambient temperature regularly falls below -20 °C.4
- The document applies to LT-32 turbines of all variants with the Fabrikam FGT-3200 gearbox.1
- The LT-32 uses a Fabrikam FGT-3200 three-stage gearbox with one planetary stage followed by two parallel helical stages.2
- The FGT-3200 gearbox rated input torque is 2,410 kNm and its dry mass is 21.6 t.2
- Only the lubricant listed in Table 4-2 is approved for the FGT-3200 gearbox, and lubricants of different brands or viscosity grades must not be mixed.3
- The asset is the WTG-07 main gearbox, a Fabrikam FGT-3200 with serial FGT-3200-18-07752.5
- The procedure applies to WTG-01 to WTG-12 with Litware LT-32 CCV turbines and Fabrikam FGT-3200 gearboxes.6
- The incident concerns WTG-07, serial LT32-19-0421, with gearbox FGT-3200-18-07752.7
- All turbine entries are Litware LT-32 CCV turbines with Fabrikam FGT-3200 gearboxes, Hub height (m) 92, and Rotor diameter (m) 118.8910111213141516171819
- FGT-P-22328, the HSS bearing on the generator side for FGT-3200, is a critical item below minimum stock: 0 pc on hand, minimum 1 pc, reorder quantity 2 pc, and 2 pc on order under PO-76994 for expected delivery on 2026-09-25.2021
- The deck is about the Fabrikam FGT-3200 in the Litware LT-32 and is dated October 2025.22
- The configuration records checked for Quellmoor Ridge Wind Farm showed that all 12 turbines, WTG-01 through WTG-12, were delivered as LT-32 in CCV configuration with Fabrikam FGT-3200 gearboxes, so SB-LWS-2025-07 applies to all 12 turbines.23
- Superseded: The procedure applies to WTG-01 to WTG-12, specified as Litware LT-32 CCV turbines with Fabrikam FGT-3200 gearboxes.24
Timeline
- 2025-07: The configuration records checked for Quellmoor Ridge Wind Farm showed that all 12 turbines, WTG-01 through WTG-12, were delivered as LT-32 in CCV configuration with Fabrikam FGT-3200 gearboxes, so SB-LWS-2025-07 applies to all 12 turbines.23
- 2025-10: The deck is about the Fabrikam FGT-3200 in the Litware LT-32 and is dated October 2025.22
- 2026-09-25: FGT-P-22328, the HSS bearing on the generator side for FGT-3200, is a critical item below minimum stock: 0 pc on hand, minimum 1 pc, reorder quantity 2 pc, and 2 pc on order under PO-76994 for expected delivery on 2026-09-25.2021
Documents
- SB-LWS-2025-07 Rev. A - Gearbox oil viscosity grade change for LT-32 CCV turbines
- LWS-MM-GBX-32 Rev. D — LT-32 Maintenance Manual Chapter 4 Gearbox Excerpt
- Oil analysis report TR-OA-2026-0614 - WTG-07 gearbox oil
- SOP-GBX-010 Rev. B - Gearbox oil change
- 8D report INC-2026-006 - Repeated gearbox oil over-temperature on WTG-07 (revision 2026-07-10)
- Asset Register 2026 of Quellmoor Ridge Wind Farm, revision 2026-01-12
- Spare Parts Stock Snapshot 2026-07-21 for Quellmoor Ridge O&M Building
- Gearbox Fundamentals for Wind Technicians
- Email RE: LWS-TS-48213 Applicability of SB-LWS-2025-07 Rev. A to Quellmoor Ridge
- SOP-GBX-010 - Gearbox oil change, Revision A (superseded)
Related
- Topics: Cold-climate operation and icing, Gearbox lubrication and oil changes, Gearbox temperature, vibration and oil analysis, Generator brushes and electrical systems, Grid connection and grid operator instructions, Safety, isolation and work at height, Spare parts, stock levels and supply, Training, site rules and acronyms
Sources
Footnotes
-
LWS-MM-GBX-32 Rev. D — LT-32 Maintenance Manual Chapter 4 Gearbox Excerpt — p. 1 · ✓ quote verified ↩ ↩2
-
LWS-MM-GBX-32 Rev. D — LT-32 Maintenance Manual Chapter 4 Gearbox Excerpt — p. 2 · ✓ quote verified ↩ ↩2 ↩3 ↩4
-
LWS-MM-GBX-32 Rev. D — LT-32 Maintenance Manual Chapter 4 Gearbox Excerpt — p. 3 · ✓ quote verified ↩ ↩2
-
SB-LWS-2025-07 Rev. A - Gearbox oil viscosity grade change for LT-32 CCV turbines — p. 1 · ✓ quote verified ↩
-
Oil analysis report TR-OA-2026-0614 - WTG-07 gearbox oil — p. 1 · ✓ quote verified ↩
-
SOP-GBX-010 Rev. B - Gearbox oil change — table 1, row 7 · table ↩
-
8D report INC-2026-006 - Repeated gearbox oil over-temperature on WTG-07 (revision 2026-07-10) — table 1, row 3 · table ↩
-
Asset Register 2026 of Quellmoor Ridge Wind Farm, revision 2026-01-12 — sheet "Turbines", row 2 · table ↩
-
Asset Register 2026 of Quellmoor Ridge Wind Farm, revision 2026-01-12 — sheet "Turbines", row 3 · table ↩
-
Asset Register 2026 of Quellmoor Ridge Wind Farm, revision 2026-01-12 — sheet "Turbines", row 4 · table ↩
-
Asset Register 2026 of Quellmoor Ridge Wind Farm, revision 2026-01-12 — sheet "Turbines", row 5 · table ↩
-
Asset Register 2026 of Quellmoor Ridge Wind Farm, revision 2026-01-12 — sheet "Turbines", row 6 · table ↩
-
Asset Register 2026 of Quellmoor Ridge Wind Farm, revision 2026-01-12 — sheet "Turbines", row 7 · table ↩
-
Asset Register 2026 of Quellmoor Ridge Wind Farm, revision 2026-01-12 — sheet "Turbines", row 8 · table ↩
-
Asset Register 2026 of Quellmoor Ridge Wind Farm, revision 2026-01-12 — sheet "Turbines", row 9 · table ↩
-
Asset Register 2026 of Quellmoor Ridge Wind Farm, revision 2026-01-12 — sheet "Turbines", row 10 · table ↩
-
Asset Register 2026 of Quellmoor Ridge Wind Farm, revision 2026-01-12 — sheet "Turbines", row 11 · table ↩
-
Asset Register 2026 of Quellmoor Ridge Wind Farm, revision 2026-01-12 — sheet "Turbines", row 12 · table ↩
-
Asset Register 2026 of Quellmoor Ridge Wind Farm, revision 2026-01-12 — sheet "Turbines", row 13 · table ↩
-
Spare Parts Stock Snapshot 2026-07-21 for Quellmoor Ridge O&M Building — sheet "About", row 3 · table ↩ ↩2
-
Spare Parts Stock Snapshot 2026-07-21 for Quellmoor Ridge O&M Building — sheet "Stock", row 2 · table ↩ ↩2
-
Gearbox Fundamentals for Wind Technicians — slide 1 · ✓ quote verified ↩ ↩2
-
Email RE: LWS-TS-48213 Applicability of SB-LWS-2025-07 Rev. A to Quellmoor Ridge — message body, lines 10–12 · paraphrase ↩ ↩2
-
SOP-GBX-010 - Gearbox oil change, Revision A — table 1, row 7 · table ↩
Provenance badges✓ quote verified the quoted words were found verbatim in the source textparaphrase reworded from the source text; numbers checked, no verbatim quotetable values parsed deterministically from the cited table rows