FICTIONAL SAMPLE - Contoso Renewables, Quellmoor Ridge Wind Farm and every organisation, person, product and value in this wiki are invented. Not for operational use.

The oil filter element is a component identified by part number FGT-P-11872.123 It is used in gearbox oil change and oil filter element replacement tasks, including the scheduled MP-GBX-02 task every 12 months.234 It is replaced during the LT-32 CCV turbine conversion and in response to gearbox oil filter differential pressure high alarm A2140.567

Facts

  • The oil filter element FGT-P-11872 must be replaced during the conversion.5
  • Per turbine, parts and labour include 470 L of Proseware PWG 220, one FGT-P-11872 oil filter element, one PWG 220 label kit, and labour by 2 technicians for about 6 hours.1
  • Alarm A2140, Gearbox oil filter differential pressure high at 2.5 bar, can be caused by a clogged filter element or cold oil; the action is to replace filter element FGT-P-11872.6
  • One oil filter element FGT-P-11872 is required.23
  • Gearbox oil filter element replacement task MP-GBX-02 uses part FGT-P-11872, is scheduled every 12 months, and references SOP-GBX-010.4
  • WTG-12 raised A2140 Gearbox oil filter differential pressure high at 2.56 bar on 2026-08-02 and cleared it at 1.90 bar later the same day.89
  • WTG-04 raised A2140 Gearbox oil filter differential pressure high at 2.89 bar on 2026-08-11 17:18:08 and cleared it at 1.90 bar on 2026-08-11 18:22:08.1011
  • WTG-06 had A2140 Gearbox oil filter differential pressure high raised at 2.89 bar and cleared at 1.90 bar on 2026-08-31.1213
  • The oil filter element FGT-P-11872 is to be replaced during the conversion.7
  • After switching from PWG 320 to PWG 220, oil filter element FGT-P-11872 is to be changed a second time after 500 operating hours because loosened deposits collect in the filter.14
  • At the same time as the second oil filter element change, the supplier recommends an oil sample.14

Timeline

  • 2026-08-02: WTG-12 raised A2140 Gearbox oil filter differential pressure high at 2.56 bar on 2026-08-02 and cleared it at 1.90 bar later the same day.89
  • 2026-08-11: WTG-04 raised A2140 Gearbox oil filter differential pressure high at 2.89 bar on 2026-08-11 17:18:08 and cleared it at 1.90 bar on 2026-08-11 18:22:08.1011
  • 2026-08-31: WTG-06 had A2140 Gearbox oil filter differential pressure high raised at 2.89 bar and cleared at 1.90 bar on 2026-08-31.1213

Documents

Sources

Footnotes

  1. SB-LWS-2025-07 Rev. A - Gearbox oil viscosity grade change for LT-32 CCV turbines — p. 2 · ✓ quote verified ↩ ↩2

  2. SOP-GBX-010 Rev. B - Gearbox oil change — ¶ 23 · ✓ quote verified ↩ ↩2 ↩3

  3. SOP-GBX-010 - Gearbox oil change, Revision A — ¶ 20 · ✓ quote verified ↩ ↩2 ↩3

  4. Maintenance Plan 2026, Issue 2 — Quellmoor Ridge Wind Farm — sheet "Tasks", row 3 · table ↩ ↩2

  5. SB-LWS-2025-07 Rev. A - Gearbox oil viscosity grade change for LT-32 CCV turbines — p. 1 · ✓ quote verified ↩ ↩2

  6. LWS-MM-GBX-32 Rev. D — LT-32 Maintenance Manual Chapter 4 Gearbox Excerpt — p. 5 · ✓ quote verified ↩ ↩2

  7. Email RE: LWS-TS-48213 Applicability of SB-LWS-2025-07 Rev. A to Quellmoor Ridge — message body, lines 16–23 · ✓ quote verified ↩ ↩2

  8. SCADA alarm and status log, 2026-04-01 to 2026-08-31 — row 1436 · table ↩ ↩2

  9. SCADA alarm and status log, 2026-04-01 to 2026-08-31 — row 1485 · table ↩ ↩2

  10. SCADA alarm and status log, 2026-04-01 to 2026-08-31 — row 1654 · table ↩ ↩2

  11. SCADA alarm and status log, 2026-04-01 to 2026-08-31 — row 1655 · table ↩ ↩2

  12. SCADA alarm and status log, 2026-04-01 to 2026-08-31 — row 1896 · table ↩ ↩2

  13. SCADA alarm and status log, 2026-04-01 to 2026-08-31 — row 1897 · table ↩ ↩2

  14. Fabrikam Supplier Note on PO-76994 HSS Bearings and PWG 220 Follow-up — lines 13–15 · ✓ quote verified ↩ ↩2

Provenance badges✓ quote verified the quoted words were found verbatim in the source texttable values parsed deterministically from the cited table rows