FICTIONAL SAMPLE - Contoso Renewables, Quellmoor Ridge Wind Farm and every organisation, person, product and value in this wiki are invented. Not for operational use.

WTG-09 is a wind turbine at Quellmoor Ridge Wind Farm.123456789101112 Its gearbox oil conversion to PWG 220 is pending under SB-LWS-2025-07, and the completed gearbox oil conversion work order WO-25-0309 is recorded separately.1314 In 2026, WTG-09 had a generator brush replacement work order completed and a leading-edge erosion finding on blade C.1516

Facts

  • On 2025-01-21 at -24.6 °C, WTG-02 and WTG-09 needed more than 6 hours of heating before starting.17
  • Finding F-04 is category 3 leading-edge erosion on WTG-09 blade C, with erosion between radius 50 m and 57 m, exposed laminate over 0.3 m, and a required leading-edge repair within 6 months.15
  • WTG-09 has gearbox oil conversion to PWG 220 pending and deferred under SB-LWS-2025-07.13
  • On 2026-04-01, icing alarms A7001 led to S600 Stopped - icing status starts for WTG-12, WTG-09, WTG-03, and WTG-02, with later clears and S600 ends recorded for each turbine in this part.1819202122232425
  • On 2026-04-02, WTG-08 and WTG-09 raised A2120 Gearbox oil pressure low at 0.59 bar and later cleared at 1.35 bar.26272829
  • WTG-09 had A3210 Generator brush wear limit reached raised on 2026-07-16 and cleared on 2026-07-18; WTG-09 was also in S310 Maintenance mode on 2026-07-18 from 07:58:12 to 11:52:40.30313233
  • The movements sheet records a 2026-07-18 issue of quantity -1 for LWS-P-51207 against WO-26-0436 for WTG-09.34
  • The WTG-09 gearbox oil conversion work order WO-25-0309 was deferred because the access road was closed by snow on 2025-11-24 and was completed on 2026-01-20.14
  • WO-26-0436 for WTG-09 replaced generator brushes for A3210, was completed under WI-GEN-014, used part LWS-P-51207 quantity 1, and notes the shortest brush was 16 mm.16
  • WTG-09 in 2026-01 recorded availability_pct 96.1, energy_mwh 955.9, downtime_h 29.0, and alarm_count 15.35
  • The turbine labels shown on the plan are WTG-01, WTG-02, WTG-03, WTG-04, WTG-05, WTG-06, WTG-07, WTG-08, WTG-09, WTG-10, WTG-11, and WTG-12.123456789101112
  • WTG-09 had its generator brushes replaced under work order WO-26-0436 following alarm A3210 from 16/07.36
  • For WTG-09, the shortest measured brush was B3 at 16 mm, below the 18 mm threshold in WI-GEN-014.36
  • For WTG-09, a complete LWS-P-51207 set was replaced and the brush-holder screws were tightened to 12 N·m.36
  • WTG-09 was put through run-in at 50 % power for 8 hours, until 20:00 that evening.36
  • The next team was asked to check the end of the WTG-09 run-in at 20:00 and return it to 100 % power.37
  • PWG 220 conversion status was: nine turbines completed, WTG-11 being converted that day, WTG-12 scheduled for the following Wednesday, and WTG-09 planned for the twenty-fourth if the access road remained open.3839
  • From minus twenty, heaters need about four hours to bring the sump to plus five; the previous January, WTG-02 and WTG-09 needed more than six hours.40
  • If WTG-09 still has PWG 320 in January, its start temperature remains plus ten until conversion is complete; the parameter is changed only with the new oil.41

Timeline

  • 2025-01-21: On 2025-01-21 at -24.6 °C, WTG-02 and WTG-09 needed more than 6 hours of heating before starting.17
  • 2025-07: WTG-09 has gearbox oil conversion to PWG 220 pending and deferred under SB-LWS-2025-07.13
  • 2025-11-24: The WTG-09 gearbox oil conversion work order WO-25-0309 was deferred because the access road was closed by snow on 2025-11-24 and was completed on 2026-01-20.14
  • 2026-01: WTG-09 in 2026-01 recorded availability_pct 96.1, energy_mwh 955.9, downtime_h 29.0, and alarm_count 15.35
  • 2026-04-01: On 2026-04-01, icing alarms A7001 led to S600 Stopped - icing status starts for WTG-12, WTG-09, WTG-03, and WTG-02, with later clears and S600 ends recorded for each turbine in this part.1819202122232425
  • 2026-04-02: On 2026-04-02, WTG-08 and WTG-09 raised A2120 Gearbox oil pressure low at 0.59 bar and later cleared at 1.35 bar.26272829
  • 2026-07-16: WTG-09 had A3210 Generator brush wear limit reached raised on 2026-07-16 and cleared on 2026-07-18; WTG-09 was also in S310 Maintenance mode on 2026-07-18 from 07:58:12 to 11:52:40.30313233
  • 2026-07-18: The movements sheet records a 2026-07-18 issue of quantity -1 for LWS-P-51207 against WO-26-0436 for WTG-09.34

Documents

Sources

Footnotes

  1. Quellmoor Ridge Wind Farm Site Layout Plan - Rev. C — region 5 · OCR ↩ ↩2

  2. Quellmoor Ridge Wind Farm Site Layout Plan - Rev. C — region 6 · OCR ↩ ↩2

  3. Quellmoor Ridge Wind Farm Site Layout Plan - Rev. C — region 9 · OCR ↩ ↩2

  4. Quellmoor Ridge Wind Farm Site Layout Plan - Rev. C — region 10 · OCR ↩ ↩2

  5. Quellmoor Ridge Wind Farm Site Layout Plan - Rev. C — region 11 · OCR ↩ ↩2

  6. Quellmoor Ridge Wind Farm Site Layout Plan - Rev. C — region 13 · OCR ↩ ↩2

  7. Quellmoor Ridge Wind Farm Site Layout Plan - Rev. C — region 12 · OCR ↩ ↩2

  8. Quellmoor Ridge Wind Farm Site Layout Plan - Rev. C — region 14 · OCR ↩ ↩2

  9. Quellmoor Ridge Wind Farm Site Layout Plan - Rev. C — region 16 · OCR ↩ ↩2

  10. Quellmoor Ridge Wind Farm Site Layout Plan - Rev. C — region 18 · OCR ↩ ↩2

  11. Quellmoor Ridge Wind Farm Site Layout Plan - Rev. C — region 20 · OCR ↩ ↩2

  12. Quellmoor Ridge Wind Farm Site Layout Plan - Rev. C — region 21 · OCR ↩ ↩2

  13. Asset Register 2026 of Quellmoor Ridge Wind Farm, revision 2026-01-12 — sheet "Turbines", row 10 · table ↩ ↩2 ↩3

  14. Work Orders Export through 2026-08-31 — row 10 · table ↩ ↩2 ↩3

  15. Blade inspection report WBS-2026-031 - Quellmoor Ridge Wind Farm (May 2026) — p. 2 · ✓ quote verified ↩ ↩2

  16. Work Orders Export through 2026-08-31 — row 78 · table ↩ ↩2

  17. MOC-2025-012 - Gearbox Oil Grade Change to PWG 220 — ¶ 6 · ✓ quote verified ↩ ↩2

  18. SCADA alarm and status log, 2026-04-01 to 2026-08-31 — row 4 · table ↩ ↩2

  19. SCADA alarm and status log, 2026-04-01 to 2026-08-31 — row 5 · table ↩ ↩2

  20. SCADA alarm and status log, 2026-04-01 to 2026-08-31 — row 6 · table ↩ ↩2

  21. SCADA alarm and status log, 2026-04-01 to 2026-08-31 — row 7 · table ↩ ↩2

  22. SCADA alarm and status log, 2026-04-01 to 2026-08-31 — row 8 · table ↩ ↩2

  23. SCADA alarm and status log, 2026-04-01 to 2026-08-31 — row 9 · table ↩ ↩2

  24. SCADA alarm and status log, 2026-04-01 to 2026-08-31 — row 12 · table ↩ ↩2

  25. SCADA alarm and status log, 2026-04-01 to 2026-08-31 — row 13 · table ↩ ↩2

  26. SCADA alarm and status log, 2026-04-01 to 2026-08-31 — row 32 · table ↩ ↩2

  27. SCADA alarm and status log, 2026-04-01 to 2026-08-31 — row 33 · table ↩ ↩2

  28. SCADA alarm and status log, 2026-04-01 to 2026-08-31 — row 34 · table ↩ ↩2

  29. SCADA alarm and status log, 2026-04-01 to 2026-08-31 — row 35 · table ↩ ↩2

  30. SCADA alarm and status log, 2026-04-01 to 2026-08-31 — row 1281 · table ↩ ↩2

  31. SCADA alarm and status log, 2026-04-01 to 2026-08-31 — row 1317 · table ↩ ↩2

  32. SCADA alarm and status log, 2026-04-01 to 2026-08-31 — row 1313 · table ↩ ↩2

  33. SCADA alarm and status log, 2026-04-01 to 2026-08-31 — row 1318 · table ↩ ↩2

  34. Spare Parts Stock Snapshot 2026-07-21 for Quellmoor Ridge O&M Building — sheet "Movements", row 10 · table ↩ ↩2

  35. KPI Export 2026-H1 — row 10 · table ↩ ↩2

  36. Shift Handover Note - Day Shift - 18/07/2026 — lines 6–12 · ✓ quote verified ↩ ↩2 ↩3 ↩4

  37. Shift Handover Note - Day Shift - 18/07/2026 — lines 14–15 · ✓ quote verified ↩

  38. Toolbox Talk: Cold-Weather Start-Up After PWG 220 Conversion — 00:11–00:19 · ✓ quote verified ↩

  39. Toolbox Talk: Cold-Weather Start-Up After PWG 220 Conversion — 00:19–00:27 · ✓ quote verified ↩

  40. Toolbox Talk: Cold-Weather Start-Up After PWG 220 Conversion — 00:45–00:56 · ✓ quote verified ↩

  41. Toolbox Talk: Cold-Weather Start-Up After PWG 220 Conversion — 01:15–01:23 · ✓ quote verified ↩

Provenance badges✓ quote verified the quoted words were found verbatim in the source texttable values parsed deterministically from the cited table rowsOCR text recognised from an image; compare it with the image